Search Results

Now showing 1 - 10 of 19
  • Article
    Citation - WoS: 1
    Citation - Scopus: 1
    Left Ventricular Geometry as a Predictor of Carotid Artery Stenosis Severity in Patients Undergoing Carotid Artery Stenting
    (Wiley, 2020) Karaduman, Bilge Duran; Ayhan, Huseyin; Keles, Telat; Bozkurt, Engin
    Background and Aim Cerebrovascular diseases are the second most common cause of death worldwide. Moderate and severe carotid artery stenosis causes nearly 10% of all strokes. LV geometry is a familiar prognostic and diagnostic factor in several populations; yet, data on its role in carotid artery stenosis are unknown. In our study, we investigated the prognostic value of LV geometry in predicting carotid artery stenosis severity in patients undergoing carotid artery stenting. Methods Patients who underwent carotid artery stenting between January 2012 and January 2016 at our tertiary care center were evaluated retrospectively. Two hundred fifty-five patients who underwent carotid artery stenting were included in the study. Accessible echocardiographic documentation of ninety-eight patients was accessed and evaluated. Results LV normal geometry was detected in 37 (37.7%) of the 98 carotid artery stenting (CAS) patients, concentric hypertrophy in 13 (13.2%), eccentric hypertrophy in 9 (9.1%), and concentric remodeling in 39 (39.7%). By a majority, distal filter was used in normal geometry and eccentric hypertrophy groups (82.9% vs 100%, P: .017). Considering the relationship between carotid artery stenosis severity and LV geometry, we determined that the stenosis severity was statistically significantly higher in the concentric hypertrophy group (p:0.012). However, although no complications were detected in the concentric hypertrophy group, it did not reach statistical significance between the groups (P: .058). LVMi and as expected, Doppler velocity showed a significant correlation with stenosis severity (r = .23 vs .54; P: .021, <.001, respectively). Conclusion Echocardiographic evaluation of LV geometry provided prognostic information in the development of carotid artery stenosis. Abnormal LV geometry is an independent predictor in detecting the severity of carotid artery stenosis undergoing carotid artery stenting.
  • Editorial
    Citation - Scopus: 1
    The Playmaker of the Mitral Valve Disease: Mitral Annulus
    (Elsevier Ireland Ltd, 2020) Karaduman, Bilge Duran; Ayhan, Huseyin; Keles, Telat; Bozkurt, Engin
    [No Abstract Available]
  • Article
    Citation - WoS: 2
    Citation - Scopus: 2
    Transcatheter valve-in-valve implantation Edwards Sapien XT in a direct flow valve after early degeneration
    (Wiley-hindawi, 2020) Duran Karaduman, Bilge; Ayhan, Huseyin; Bulguroglu, Serkan; Keles, Telat; Bozkurt, Engin
    In recent years, the use of bioprosthetic valve (BPV) has increased significantly with both surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) due to reasons such as the advantage of not using anticoagulants. Nevertheless, major disadvantage of all BPV is the risk of early structural valve deterioration, leading to valve dysfunction, and requires reoperation, which significantly increases the risk of mortality or major morbidity especially after SAVR. There are a limited number of TAV-in-TAV case reports due to TAVI BPV degeneration. In our knowledge, this is the second report of TAV-in-TAV implantation wherein a previously implanted transfemoral 25-mm nonmetallic Direct Flow SVD valve treated with ViV TAVI via Edwards Sapien XT.
  • Editorial
    Transcatheter Aortic Valve Implantation in Bicuspid Aortic Valve Patients With Coagulation Factor 7 and 11 Deficiency and Atrial Fibrillation
    (Kare Publ, 2023) Guney, Murat Can; Karaduman, Bilge Duran; Ayhan, Huseyin; Keles, Telat; Bozkurt, Engin
    [No Abstract Available]
  • Article
    Citation - WoS: 16
    Citation - Scopus: 19
    The Triglyceride-Glucose Index Predicts Peripheral Artery Disease Complexity
    (Tubitak Scientific & Technological Research Council Turkey, 2020) Karaduman, Bilge Duran; Ayhan, Hüseyin; Keles, Telat; Bozkurt, Engin
    Background/aim: High levels of triglyceride (TG) and fasting blood glucose (FBG) values increase atherosclerosis risk. This study\revaluates the relationship between peripheral artery disease (PAD) severity and complexity, as assessed by TransAtlantic InterSociety\rConsensus-II (TASC-II) classification and the triglyceride-glucose (TyG) index.\rMaterials and methods: A total of 71 consecutive patients with PAD (males 93%, mean age 63.3 ± 9.7), who underwent percutaneous\rperipheral intervention were included retrospectively. The patients were divided into two groups according to the angiographically\rdetected lesions. Those with TASC A-B lesions were included in Group 1, and those with TASC C-D lesions were included in Group 2.\rTyG index was calculated as formula: ln[fasting TG (mg/dL) × fasting plasma glucose (mg/dL)/2].\rResults: There were 40 patients in Group 1 (90.3% men, with a mean age of 63.6 ± 9.3 years) and 31 patients in Group 2 (96.8% men,\rwith a mean age of 62.0 ± 8.6 years). In the majority of patients in both groups, the target vessels are iliac arteries and femoral arteries.\rIn Group 2, platelet count and TyG index were significantly high, according to Group 1. The TyG index was significantly correlated with\rTASC-II, Rutherford category, HbA1c, and HDL-C.\rConclusion: In this present study, we showed that the TyG index was an independent predictor of peripheral artery disease complexity,\raccording to TASC-II classification, for the first time in the literature.
  • Article
    Citation - WoS: 1
    Citation - Scopus: 1
    Outcomes of Transcatheter Aortic Valve Implantation in Patients With and Without Diabetes Mellitus
    (Soc Brasil Cirurgia Cardiovasc, 2024) Ayhan, Huseyin; Guney, Murat Can; Keles, Telat; Bozkurt, Engin
    Introduction: Diabetes mellitus (DM) in patients undergoing cardiac transcatheter or surgical interventions usually is correlated with poor outcomes. Transcatheter aortic valve implantation (TAVI) has been developed as a therapy choice for inoperable, high-, or intermediate-risk surgical patients with severe aortic stenosis (AS). Objective: To evaluate the impact of DM and hemoglobin A1c (HbA1c) on outcomes and survival after TAVI. Methods: Five hundred and fifty-two symptomatic severe AS patients who underwent TAVI, of whom 164 (29.7%) had DM, were included in this retrospective study. Follow-up was performed after 30 days, six months, and annually. Results: The device success and risks of procedural-related complications were similar between patients with and without DM, except for acute kidney injury, which was more frequent in the DM group (2.4% vs. 0%, P=0.021). In-hospital and first-year mortality were similar between the groups (4.9% vs. 3.6%, P=0.490 and 15.0% vs. 11.2%, P=0.282, respectively). There was a statistical difference between HbA1c >= 6.5 and HbA1c <= 6.49 groups in total mortality (34.4% vs. 15.8%, P<0.001, respectively). The only independent predictors were Society of Thoracic Surgeons score (hazard ratio [HR] 1.28, 95% confidence interval [CI] 1.09-1.51; P=0.003) and HbA1c level >= 6.5 (HR 10.78, 95% CI 2.58-21.50; P=0.003) in multivariable logistic regression analysis. Conclusion: In this study, we conclude that DM was not correlated with an increased mortality risk or complication rates after TAVI. Also, it was shown that mortality was higher in patients with HbA1c >= 6.5, and it was an independent predictor for long-term mortality.
  • Editorial
    Citation - WoS: 4
    Citation - Scopus: 7
    Transcatheter Tricuspid Valve-In Implantation With a Novel Balloon Expandable Myval Thv
    (Elsevier Science inc, 2021) Karaduman, Bilge Duran; Ayhan, Huseyin; Keles, Telat; Bozkurt, Engin
    The transcatheter tricuspid valve-in-valve implantation has not yet been clarified, and several case series have documented results in patients with tricuspid bioprosthetic valve degeneration who underwent transcatheter implantation of Edwards SAPIEN XT and SAPIEN 3 (Edwards Lifesciences, Irvine, CA) and Medtronic (Minneapolis, MN) valves. Here, we present the case of a patient with severe bioprosthetic tricuspid valve stenosis who was successfully treated with the transfemoral route through the 29-mm novel balloon expandable Myval transcatheter heart valve (Meril Life Sciences Pvt Ltd, Vapi, Gujarat, India) system. (C) 2021 by The Society of Thoracic Surgeons
  • Article
    Citation - WoS: 3
    Citation - Scopus: 2
    Transcatheter Aortic Valve Implantation in Patients With Connective Tissue Disease
    (Taiwan Soc Cardiology, 2021) Ayhan, Huseyin; Karaduman, Bilge Duran; Keles, Telat; Bozkurt, Engin
    Background: There is still no consensus on the treatment of patients with connective tissue disease (CTD) with severe symptomatic aortic stenosis (AS). The aim of this study was to evaluate the feasibility and safety of transcatheter aortic valve implantation (TAVI) in patients with CTD. Methods: Five hundred and fifty consecutive symptomatic severe AS patients who underwent TAVI between 2011 and 2019 were included in this retrospective study, of whom 14 had CTD. Follow-up was performed 30 days, 6 months, and 1 year after the procedure. Results: Of the 14 (2.5%) patients who had CTD, most had rheumatoid arthritis (n = 10), followed by lupus erythematosus (n = 2), scleroderma (n = 1) and mixed (n = 1) CTD. The mean age was 77.6 +/- 7.9 years, and there was no statistical difference between the CTD and no-CTD groups. In addition, significantly more of the CTD patients (85.7%) were female compared to the no-CTD group (p = 0.018). None of the patients in the CTD group had acute kidney injury, stroke, major bleeding, or pericardial effusion. However, significantly more patients in the CTD group (n = 4) needed permanent pacemaker implantation than in the no-CTD group (p = 0.008). There were no significant differences between the two groups in terms of mean discharge time (CTD 4.6 +/- 2.0, no-CTD 4.5 +/- 2.3 days, p = 0.926) and in-hospital mortality [CTD 1 (7.1%), no-CTD 21 (3.9%); p = 0.542]. Conclusions: In this study, we presented the results of TAVI in patients with and without CTD. The TAVI procedure had similar mid-term outcomes in the two groups, and the CTD group had numerically lower rates of major complications at the cost of a higher incidence of pacemaker implantation.
  • Letter
    Citation - WoS: 2
    Citation - Scopus: 2
    Transcarotid Transcatheter Aortic Valve Implantation With a Novel Balloon Expandable Myval® Thv Under the Local Anesthesia
    (Tsinghua Univ Press, 2022) Ayhan, Huseyin; Karaduman, Bilge Duran; Keles, Telat; Uguz, Emrah; Boysan, Emre; Bozkurt, Engin
    [No Abstract Available]
  • Article
    Citation - WoS: 1
    Citation - Scopus: 1
    Karotis Arter Stentlemesinin Etkinliği ve Güvenliği: Tek Merkez Deneyimi
    (Kare Publ, 2020) Karaduman, Bilge Duran; Karaduman, Bilge Duran; Ayhan, Hüseyin; Ayhan, Hüseyin; Keles, Telat; Bozkurt, Engin; Karaduman, Bilge Duran; Ayhan, Hüseyin
    Amaç: İnternal karotis arterdeki orta ve şiddetli darlıklar tüm inmelerin %10–15’ine neden olmaktadır. Bu çalışmada, üçüncü basamak bir referans merkezde karotis arter stentlemesinin (KAS) güvenliğini ve kısa dönem etkinliğini değerlendirmeyi amaçladık. Yöntemler: Üçüncü basamak merkezimizde Ocak 2017 ile Mayıs 2018 arasında KAS uygulanan hastalar geriye dönük olarak değerlendirildi. KAS uygulanan 145 hasta çalışmaya dahil edildi. Bulgular: Hastaların ortalama yaşı 70.1±8.6 yıl idi ve tüm grubun %75.2’si erkek olup %37.9’unda hipertansiyon mevcuttu. Hastaların 81’i (%55.9) semptomatik, 64’ü (%44.1) asemptomatik olarak gruplandırıldı. Semptomatik hastalarda koroner girişimler daha çok KAS sonrası (%38.9) yapılırken, asemptomatik grupta ise KAS öncesi (%25.9) ve sonrasında (%25.9) benzer oranlarda yapıldığı görüldü ama gruplar arasında istatistiksel fark yoktu. Semptomatik hastalarda (%59.2), asemptomatik hastalarda (%78.7) olduğu gibi distal emboli koruyucu cihaz (EKC), proksimal EKC’ye göre daha fazla kullanıldı. Ancak proksimal EKC, semptomatik hastalarda asemptomatik hastalara kıyasla anlamlı olarak daha fazla kullanıldı. Hastane içi ölüm görülmedi ve tüm popülasyonda 5 (%3.4) hastada inme veya geçici iskemik atak (GİA) gözlendi. Asemptomatik grupta GİA veya inme gözlenmedi, semptomatik grupta 2 hastada (%2.4) inme ve 3 hastada (%3.7) GİA görüldü. Sonuç: Bu çalışma kabul edilebilir komplikasyon oranları ile KAS’ın güvenirliğini ve uygulanabilirliğini ortaya koymuştur. KAS prosedürü, deneyimli girişimciler tarafından optimal tıbbi tedavi altında, agresif risk modifikasyonu ile EKC kullanılarak, uygun hastalarda en az komplikasyonla gerçekleştirilmelidir.