Search Results

Now showing 1 - 3 of 3
  • Article
    Citation - WoS: 113
    Citation - Scopus: 133
    Identification of Meat Species by Using Laser-Induced Breakdown Spectroscopy
    (Elsevier Sci Ltd, 2016) Bilge, Gonca; Velioglu, Hasan Murat; Sezer, Banu; Eseller, Kemal Efe; Boyaci, Ismail Hakki
    The aim of the present study is to identify meat speciesby using laser-induced breakdown spectroscopy (LIBS). Elemental composition differences between meat species were used for meat identification. For this purpose, certain amounts of pork, beef and chicken were collected from different sources and prepared as pellet form for LIBS measurements. The obtained LIBS spectra were evaluated with some chemometric methods, and meat species were qualitatively discriminated with principal component analysis (PCA) method with 83.37% ratio. Pork beef and chicken-beef meat mixtures were also analyzed with partial least square (PLS) method quantitatively. Determination coefficient (R-2) and limit of detection (LOD) values were found as 0.994 and 4.4% for pork adulterated beef, and 0.999 and 2.0% for chicken adulterated beef, respectively. In the light of the findings, it was seen that LIBS can be a valuable tool for quality control measurements of meat as a routine method. (C) 2016 Elsevier Ltd. All rights reserved.
  • Article
    Citation - WoS: 15
    Citation - Scopus: 17
    Performance Evaluation of Laser Induced Breakdown Spectroscopy in the Measurement of Liquid and Solid Samples
    (Pergamon-elsevier Science Ltd, 2018) Bilge, Gonca; Sezer, Banu; Boyaci, Ismail Hakki; Eseller, Kemal Efe; Berberoglu, Halil
    Liquid analysis by using LIBS is a complicated process due to difficulties encountered during the collection of light and formation of plasma in liquid. To avoid these, some applications are performed such as aerosol formation and transforming liquid into solid state. However, performance of LIBS in liquid samples still remains a challenging issue. In this study, performance evaluation of LIBS and parameter optimizations in liquid and solid phase samples were performed. For this purpose,milk was chosen as model sample; milk powder was used as solid sample, and milk was used as liquid sample in the experiments. Different experimental setups have been constructed for each sampling technique, and optimizations were performed to determine suitable parameters such as delay time, laser energy, repetition rate and speed of rotary table for solid sampling technique,and flow rate of carrier gas for liquid sampling technique. Target element was determined as Ca, which is a critically important element in milk for determining its nutritional value and Ca addition. In optimum parameters, limit of detection (LOD), limit of quantification (LOQ) and relative standard deviation (RSD) values were calculated as 0.11%, 0.36% and 8.29% respectively for milk powders samples; while LOD, LOQ and RSD values were calculated as 0.24%, 0.81%, and 10.93% respectively for milk samples. It can be said that LIBS is an applicable method in both liquid and solid samples with suitable systems and parameters. However, liquid analysis requires much more developed systems for more accurate results. (C) 2018 Elsevier B.V.All rights reserved.
  • Article
    Citation - WoS: 54
    Citation - Scopus: 68
    Analysis of Bakery Products by Laser-Induced Breakdown Spectroscopy
    (Elsevier Sci Ltd, 2015) Bilge, Gonca; Boyaci, Ismail Hakki; Eseller, Kemal Efe; Tamer, Ugur; Cakir, Serhat
    In this study, we focused on the detection of Na in bakery products by using laser-induced breakdown spectroscopy (LIBS) as a quick and simple method. LIBS experiments were performed to examine the Na at 589 nm to quantify NaCl. A series of standard bread sample pellets containing various concentrations of NaCl (0.025-3.5%) were used to construct the calibration curves and to determine the detection limits of the measurements. Calibration graphs were drawn to indicate functions of NaCl and Na concentrations, which showed good linearity in the range of 0.025-3.5% NaCl and 0.01-1.4% Na concentrations with correlation coefficients (R-2) values greater than 0.98 and 0.96. The obtained detection limits for NaCl and Na were 175 and 69 ppm, respectively. Performed experimental studies showed that LIBS is a convenient method for commercial bakery products to quantify NaCl concentrations as a rapid and in situ technique. (C) 2015 Elsevier Ltd. All rights reserved.