The Relationship Between Soong Classification and Fracture Characteristics with Implant Removal for Distal Radius Fractures: A Comparative Study of 795 Cases

Loading...
Publication Logo

Date

2025

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier Masson, Corp Off

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Average
Popularity
Average

Research Projects

Journal Issue

Abstract

Introduction: Although there is no consensus in the literature, it is believed that the Soong classification system and fracture pattern are risk factors for plate removal in distal radius fractures. Hypothesis: The aim of this large-scale study was to evaluate the relationship between Soong classification, fracture pattern, and implant removal in distal radius fractures. Materials and methods: We retrospectively evaluated 795 patients who underwent surgery using a volar locking plate for distal radius fractures at our clinic between 2005 and 2022. The patients were divided into two groups: implant removed, and implant retained. The groups were examined for demographic data, follow-up periods, fracture classifications, and radiological parameters. Additionally, the patients were divided into groups and compared according to the Soong classification, which was determined according to implant placement. Indications for implant removal were also included in this study, and their relationships with other parameters were evaluated. Results: A total of 123 and 672 patients were included in the implant removed and retained groups, respectively. The average age of the implant removed group was significantly lower (p = 0.005). There were no significant differences between the two groups in terms of fracture classification or other radiological parameters. In the implant removed group, the rate of grade 2, according to the Soong classification, was statistically higher than that in the other groups (p = 0.019). Flexor tenosynovitis was the most common reason for implant removal. Conclusion: The Soong classification system is an important risk factor associated with implant removal. This risk may increase, particularly among young patients. Surgeons should consider placing the distal radius locking plate as proximally as possible to reduce the frequency of implant removal. Level of evidence: III; retrospective comparative study

Description

Yogun, Yener/0000-0002-3070-5509; Gezer, Mehmet Can/0000-0001-7034-2522;

Keywords

Ao/Ota Classification, Distal Radius Fracture, Implant Removal, Soong Classification, Volar Locking Plate

Fields of Science

Citation

WoS Q

Q2

Scopus Q

Q1
OpenCitations Logo
OpenCitations Citation Count
N/A

Source

Orthopaedics & Traumatology-Surgery & Research

Volume

111

Issue

5

Start Page

104172

End Page

Collections

PlumX Metrics
Citations

Scopus : 1

Captures

Mendeley Readers : 3

SCOPUS™ Citations

1

checked on Feb 19, 2026

Page Views

4

checked on Feb 19, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
6.62138127

Sustainable Development Goals