Transcatheter valve-in-valve implantation Edwards Sapien XT in a direct flow valve after early degeneration

dc.authorid AYHAN, Hüseyin/0000-0002-9991-7307
dc.authorid Bulguroglu, Serkan/0000-0001-5949-9940
dc.authorscopusid 56655177100
dc.authorscopusid 26530826900
dc.authorscopusid 57216321743
dc.authorscopusid 6603167404
dc.authorscopusid 7003971982
dc.authorwosid Karaduman, Bilge Duran/ABC-1759-2020
dc.authorwosid AYHAN, Hüseyin/A-5176-2018
dc.contributor.author Duran Karaduman, Bilge
dc.contributor.author Ayhan, Huseyin
dc.contributor.author Bulguroglu, Serkan
dc.contributor.author Keles, Telat
dc.contributor.author Bozkurt, Engin
dc.date.accessioned 2024-07-05T15:39:56Z
dc.date.available 2024-07-05T15:39:56Z
dc.date.issued 2020
dc.department Atılım University en_US
dc.department-temp [Duran Karaduman, Bilge; Ayhan, Huseyin] Atilim Univ, Medicana Int Ankara Hosp, Dept Cardiol, Fac Med, TR-06510 Ankara, Turkey; [Bulguroglu, Serkan; Keles, Telat] Ankara Yildirim Beyazit Univ, Ankara City Hosp, Dept Cardiol, Fac Med, Ankara, Turkey; [Bozkurt, Engin] Medicana Int Ankara Hosp, Dept Cardiol, Ankara, Turkey en_US
dc.description AYHAN, Hüseyin/0000-0002-9991-7307; Bulguroglu, Serkan/0000-0001-5949-9940 en_US
dc.description.abstract In recent years, the use of bioprosthetic valve (BPV) has increased significantly with both surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) due to reasons such as the advantage of not using anticoagulants. Nevertheless, major disadvantage of all BPV is the risk of early structural valve deterioration, leading to valve dysfunction, and requires reoperation, which significantly increases the risk of mortality or major morbidity especially after SAVR. There are a limited number of TAV-in-TAV case reports due to TAVI BPV degeneration. In our knowledge, this is the second report of TAV-in-TAV implantation wherein a previously implanted transfemoral 25-mm nonmetallic Direct Flow SVD valve treated with ViV TAVI via Edwards Sapien XT. en_US
dc.identifier.citationcount 1
dc.identifier.doi 10.1111/jocs.15016
dc.identifier.endpage 3595 en_US
dc.identifier.issn 0886-0440
dc.identifier.issn 1540-8191
dc.identifier.issue 12 en_US
dc.identifier.pmid 32939855
dc.identifier.scopus 2-s2.0-85090987627
dc.identifier.startpage 3592 en_US
dc.identifier.uri https://doi.org/10.1111/jocs.15016
dc.identifier.uri https://hdl.handle.net/20.500.14411/3261
dc.identifier.volume 35 en_US
dc.identifier.wos WOS:000569520400001
dc.identifier.wosquality Q3
dc.institutionauthor Ayhan, Hüseyin
dc.institutionauthor Karaduman, Bilge Duran
dc.language.iso en en_US
dc.publisher Wiley-hindawi en_US
dc.relation.publicationcategory Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.scopus.citedbyCount 2
dc.subject bioprosthetic valve en_US
dc.subject repeat TAVI en_US
dc.subject structural valve deterioration en_US
dc.subject valve-in-valve en_US
dc.title Transcatheter valve-in-valve implantation Edwards Sapien XT in a direct flow valve after early degeneration en_US
dc.type Article en_US
dc.wos.citedbyCount 2
dspace.entity.type Publication
relation.isAuthorOfPublication e2abe0c2-2077-48dd-9867-1fcddc073f93
relation.isAuthorOfPublication 0f73438e-c5d8-48a7-9ee7-f34c94ea2421
relation.isAuthorOfPublication.latestForDiscovery e2abe0c2-2077-48dd-9867-1fcddc073f93

Files

Collections