Transcatheter valve-in-valve implantation Edwards Sapien XT in a direct flow valve after early degeneration

dc.authoridAYHAN, Hüseyin/0000-0002-9991-7307
dc.authoridBulguroglu, Serkan/0000-0001-5949-9940
dc.authorscopusid56655177100
dc.authorscopusid26530826900
dc.authorscopusid57216321743
dc.authorscopusid6603167404
dc.authorscopusid7003971982
dc.authorwosidKaraduman, Bilge Duran/ABC-1759-2020
dc.authorwosidAYHAN, Hüseyin/A-5176-2018
dc.contributor.authorDuran Karaduman, Bilge
dc.contributor.authorAyhan, Huseyin
dc.contributor.authorBulguroglu, Serkan
dc.contributor.authorKeles, Telat
dc.contributor.authorBozkurt, Engin
dc.date.accessioned2024-07-05T15:39:56Z
dc.date.available2024-07-05T15:39:56Z
dc.date.issued2020
dc.departmentAtılım Universityen_US
dc.department-temp[Duran Karaduman, Bilge; Ayhan, Huseyin] Atilim Univ, Medicana Int Ankara Hosp, Dept Cardiol, Fac Med, TR-06510 Ankara, Turkey; [Bulguroglu, Serkan; Keles, Telat] Ankara Yildirim Beyazit Univ, Ankara City Hosp, Dept Cardiol, Fac Med, Ankara, Turkey; [Bozkurt, Engin] Medicana Int Ankara Hosp, Dept Cardiol, Ankara, Turkeyen_US
dc.descriptionAYHAN, Hüseyin/0000-0002-9991-7307; Bulguroglu, Serkan/0000-0001-5949-9940en_US
dc.description.abstractIn recent years, the use of bioprosthetic valve (BPV) has increased significantly with both surgical aortic valve replacement (SAVR) and transcatheter aortic valve implantation (TAVI) due to reasons such as the advantage of not using anticoagulants. Nevertheless, major disadvantage of all BPV is the risk of early structural valve deterioration, leading to valve dysfunction, and requires reoperation, which significantly increases the risk of mortality or major morbidity especially after SAVR. There are a limited number of TAV-in-TAV case reports due to TAVI BPV degeneration. In our knowledge, this is the second report of TAV-in-TAV implantation wherein a previously implanted transfemoral 25-mm nonmetallic Direct Flow SVD valve treated with ViV TAVI via Edwards Sapien XT.en_US
dc.identifier.citationcount1
dc.identifier.doi10.1111/jocs.15016
dc.identifier.endpage3595en_US
dc.identifier.issn0886-0440
dc.identifier.issn1540-8191
dc.identifier.issue12en_US
dc.identifier.pmid32939855
dc.identifier.scopus2-s2.0-85090987627
dc.identifier.startpage3592en_US
dc.identifier.urihttps://doi.org/10.1111/jocs.15016
dc.identifier.urihttps://hdl.handle.net/20.500.14411/3261
dc.identifier.volume35en_US
dc.identifier.wosWOS:000569520400001
dc.identifier.wosqualityQ3
dc.institutionauthorAyhan, Hüseyin
dc.institutionauthorKaraduman, Bilge Duran
dc.language.isoenen_US
dc.publisherWiley-hindawien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.scopus.citedbyCount1
dc.subjectbioprosthetic valveen_US
dc.subjectrepeat TAVIen_US
dc.subjectstructural valve deteriorationen_US
dc.subjectvalve-in-valveen_US
dc.titleTranscatheter valve-in-valve implantation Edwards Sapien XT in a direct flow valve after early degenerationen_US
dc.typeArticleen_US
dc.wos.citedbyCount1
dspace.entity.typePublication
relation.isAuthorOfPublicatione2abe0c2-2077-48dd-9867-1fcddc073f93
relation.isAuthorOfPublication0f73438e-c5d8-48a7-9ee7-f34c94ea2421
relation.isAuthorOfPublication.latestForDiscoverye2abe0c2-2077-48dd-9867-1fcddc073f93

Files

Collections