Design of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection system

dc.authoridTümay, Ahmet/0000-0003-2799-4140
dc.authoridCavus, Enver/0000-0002-7203-9700
dc.authorscopusid57202607002
dc.authorscopusid6506466434
dc.authorscopusid21739584100
dc.authorscopusid6506478590
dc.authorwosidÖzbek, Mehmet/AAS-7777-2020
dc.authorwosidTümay, Ahmet/V-9426-2019
dc.authorwosidCavus, Enver/AAG-4449-2019
dc.contributor.authorDemir, Besir
dc.contributor.authorTumay, Ahmet
dc.contributor.authorOzbek, Mehmet Efe
dc.contributor.authorCavus, Enver
dc.contributor.otherDepartment of Electrical & Electronics Engineering
dc.date.accessioned2024-07-05T15:26:50Z
dc.date.available2024-07-05T15:26:50Z
dc.date.issued2018
dc.departmentAtılım Universityen_US
dc.department-temp[Demir, Besir] Gebze Tech Univ, Elect Engn Dept, Gebze, Turkey; [Tumay, Ahmet] Tubitak Teydeb, Ankara, Turkey; [Ozbek, Mehmet Efe] Atilim Univ, Dept Elect & Elect Engn, Ankara, Turkey; [Cavus, Enver] Ankara Yildirim Beyazit Univ, Dept Elect & Elect Engn, TR-06010 Ankara, Turkeyen_US
dc.descriptionTümay, Ahmet/0000-0003-2799-4140; Cavus, Enver/0000-0002-7203-9700en_US
dc.description.abstractBackground: In industrial disasters, early detection of problems and crisis management are critical for saving the lives of people and reducing the impact of disasters. Purpose: In this study, we design a special gateway system that bridges the gap between different communication protocols and enables legacy supervisory control and data acquisition systems to function early detection systems for potential industrial disasters. Methods: The system uses a new queue mechanism to substantially improve the problem of data loss found in conventional supervisory control and data acquisition systems and utilizes identification (ID) prioritization to enable early detection of problems. The proposed system is implemented and tested on a Linux-based, 3G-capable Modbus gateway system. Modbus is used as the communication protocol and 3G technology is utilized to provide high-speed wireless data transfer components. The Modbus gateway device uses an ARM-based EP9302 processor and has digital input/output, relay outputs, and RS485 outputs. Conclusion: This study is significant as it is the first work to show the application of the priority query execution method for Modbus gateway devices.en_US
dc.identifier.citation1
dc.identifier.doi10.1177/0020294018782087
dc.identifier.endpage212en_US
dc.identifier.issn0020-2940
dc.identifier.issn2051-8730
dc.identifier.issue7-8en_US
dc.identifier.scopus2-s2.0-85048888348
dc.identifier.startpage205en_US
dc.identifier.urihttps://doi.org/10.1177/0020294018782087
dc.identifier.urihttps://hdl.handle.net/20.500.14411/2610
dc.identifier.volume51en_US
dc.identifier.wosWOS:000446343600001
dc.identifier.wosqualityQ3
dc.institutionauthorÖzbek, Mehmet Efe
dc.language.isoenen_US
dc.publisherSage Publications Ltden_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectRemote Terminal Unit (RTU)en_US
dc.subjectTransmission Control Protocol (TCP)en_US
dc.subjectModbus gatewayen_US
dc.subjectModbus RTUen_US
dc.subjectModbus TCPen_US
dc.subjectpriority query executionen_US
dc.subject3Gen_US
dc.subjectembedded Linuxen_US
dc.subjectARMen_US
dc.subjectEP9302en_US
dc.subjectreal-time Modbus queryen_US
dc.titleDesign of a system solution that modernizes legacy supervisory control and data acquisition systems as an early detection systemen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isAuthorOfPublication8a62c8fc-1922-41ab-b665-e9d69c5f2d85
relation.isAuthorOfPublication.latestForDiscovery8a62c8fc-1922-41ab-b665-e9d69c5f2d85
relation.isOrgUnitOfPublicationc3c9b34a-b165-4cd6-8959-dc25e91e206b
relation.isOrgUnitOfPublication.latestForDiscoveryc3c9b34a-b165-4cd6-8959-dc25e91e206b

Files