New real time temperature monitoring and evaluation system

dc.authoridCoramik, Mustafa/0000-0002-3225-633X
dc.authorwosidçıtak, hakan/AIE-7954-2022
dc.authorwosidCoramik, Mustafa/AAG-9219-2019
dc.authorwosidEge, Yavuz/AAD-7800-2019
dc.contributor.authorNazlıbilek, Sedat
dc.contributor.authorKalender, Osman
dc.contributor.authorCitak, Hakan
dc.contributor.authorNazlibilek, Sedat
dc.contributor.authorCoramik, Mustafa
dc.contributor.otherDepartment of Mechatronics Engineering
dc.date.accessioned2024-10-06T11:12:18Z
dc.date.available2024-10-06T11:12:18Z
dc.date.issued2015
dc.departmentAtılım Universityen_US
dc.department-temp[Ege, Yavuz; Coramik, Mustafa] Balikesir Univ, Necatibey Fac Educ, Dept Phys, TR-10100 Balikesir, Turkey; [Kalender, Osman] Bursa Orhangazi Univ, Fac Engn, Dept Elect Elect Engn, TR-16350 Bursa, Turkey; [Citak, Hakan] Balikesir Univ, Balikesir Vocat High Sch, TR-10100 Balikesir, Turkey; [Nazlibilek, Sedat] Atilim Univ, Fac Engn, Dept Mechatron Engn, TR-06800 Ankara, Turkeyen_US
dc.descriptionCoramik, Mustafa/0000-0002-3225-633Xen_US
dc.description.abstractThe storage of many drugs, serum and vaccines at specified temperature limit is very important. Therefore, it is necessary to read and record the ambient temperature and control the refrigerating device according to the limiting values specified by the user. Taking into account these requirements, a new PIC microprocessor-based temperature monitoring system that triggers the DS18B20 temperature sensor and controls the running of the refrigerator system is designed and developed. At the controlling operation, performed by this system, temperature limits are specified by the user. In case these limit values are exceeded, a warning message is sent to the user through GSM module. Furthermore, the temperature values that are read between the time intervals specified by the user are sent to a GLCD screen and presented in a graphical form. The temperature readings can be transferred to the computer environment as text file through a Visual Basic based interface with using a serial port. At this system which has one year data storage capacity, it is possible that the temperature values can be transferred to the computer by wireless communication facility. Differently from the present systems, recording, evaluation, warning and device control operations are performed in the same system. In the present paper, the system operation and its performance at the fields of application are expressed in detail.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.citation1
dc.identifier.doi[WOS-DOI-BELIRLENECEK-217]
dc.identifier.endpage663en_US
dc.identifier.issn0019-5596
dc.identifier.issn0975-1041
dc.identifier.issue10en_US
dc.identifier.scopusqualityQ3
dc.identifier.startpage652en_US
dc.identifier.urihttps://hdl.handle.net/20.500.14411/9134
dc.identifier.volume53en_US
dc.identifier.wosWOS:000363362300002
dc.identifier.wosqualityQ4
dc.language.isoenen_US
dc.publisherNatl inst Science Communication-niscairen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectRefrigeratoren_US
dc.subjectTemperature sensoren_US
dc.subjectMicrocontrolleren_US
dc.subjectSerial porten_US
dc.subjectWireless communicationen_US
dc.titleNew real time temperature monitoring and evaluation systemen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isAuthorOfPublicationde094a03-1e24-470f-bb3b-db66e9f73b89
relation.isAuthorOfPublication.latestForDiscoveryde094a03-1e24-470f-bb3b-db66e9f73b89
relation.isOrgUnitOfPublicatione2a6d0b1-378e-4532-82b1-d17cabc56744
relation.isOrgUnitOfPublication.latestForDiscoverye2a6d0b1-378e-4532-82b1-d17cabc56744

Files

Collections