Mixed Three-State K-Out Systems With Components Entering at Different Performance Levels
dc.authorid | Triantafyllou, Ioannis S./0000-0002-7512-5217 | |
dc.authorid | Koutras, Markos/0000-0001-5160-2405 | |
dc.authorid | Eryilmaz, Serkan/0000-0002-2108-1781 | |
dc.authorscopusid | 8203625300 | |
dc.authorscopusid | 6603801481 | |
dc.authorscopusid | 23096344700 | |
dc.authorwosid | Triantafyllou, Ioannis S./HJY-6398-2023 | |
dc.authorwosid | Eryilmaz, Serkan/AAF-9349-2019 | |
dc.contributor.author | Eryilmaz, Serkan | |
dc.contributor.author | Eryılmaz, Serkan | |
dc.contributor.author | Koutras, Markos V. | |
dc.contributor.author | Triantafyllou, Ioannis S. | |
dc.contributor.other | Industrial Engineering | |
dc.date.accessioned | 2024-07-05T14:29:18Z | |
dc.date.available | 2024-07-05T14:29:18Z | |
dc.date.issued | 2016 | |
dc.department | Atılım University | en_US |
dc.department-temp | [Eryilmaz, Serkan] Atilim Univ, Dept Ind Engn, TR-06836 Ankara, Turkey; [Koutras, Markos V.; Triantafyllou, Ioannis S.] Univ Piraeus, Dept Stat & Insurance Sci, Piraeus 18534, Greece | en_US |
dc.description | Triantafyllou, Ioannis S./0000-0002-7512-5217; Koutras, Markos/0000-0001-5160-2405; Eryilmaz, Serkan/0000-0002-2108-1781 | en_US |
dc.description.abstract | In this paper, we study a three-state k-out-of-n system with n independent components (k = (k(1), k(2))). Each component can be in a perfect functioning state (state "2"), partially working (state "1"), or failed (state "0"). We assume that, at time t = 0, n(1) components are in a partially working state while the rest n(2) components are fully functioning (n = n(1) + n(2)). The system is considered to be at state "1" or above if at least k(1) components are working (fully or partially). If at least k(1) components are working and at least k(2) components are in a perfect functioning state, we shall say that the system is at state "2". In this paper, we develop formulae for the survival functions corresponding to the two different system's states described above. For illustration purposes, a numerical example which assumes that the degradation occurs according to a Markov process is presented. | en_US |
dc.identifier.citation | 7 | |
dc.identifier.doi | 10.1109/TR.2016.2521762 | |
dc.identifier.endpage | 972 | en_US |
dc.identifier.issn | 0018-9529 | |
dc.identifier.issn | 1558-1721 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.scopus | 2-s2.0-84957654995 | |
dc.identifier.startpage | 969 | en_US |
dc.identifier.uri | https://doi.org/10.1109/TR.2016.2521762 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14411/501 | |
dc.identifier.volume | 65 | en_US |
dc.identifier.wos | WOS:000382706900040 | |
dc.identifier.wosquality | Q1 | |
dc.language.iso | en | en_US |
dc.publisher | Ieee-inst Electrical Electronics Engineers inc | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | k-out-of-n systems | en_US |
dc.subject | Markov processes | en_US |
dc.subject | mean system lifetime | en_US |
dc.subject | survival function | en_US |
dc.subject | three-state systems | en_US |
dc.title | Mixed Three-State K-Out Systems With Components Entering at Different Performance Levels | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 37862217-5541-47e3-9406-e21aa38e7fdf | |
relation.isAuthorOfPublication.latestForDiscovery | 37862217-5541-47e3-9406-e21aa38e7fdf | |
relation.isOrgUnitOfPublication | 12c9377e-b7fe-4600-8326-f3613a05653d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 12c9377e-b7fe-4600-8326-f3613a05653d |