Yielding of Two-Layer Shrink-Fitted Composite Tubes Subject To Radial Pressure

dc.authoridAkis, Tolga/0000-0002-6754-4497
dc.authorscopusid7003983781
dc.authorscopusid7801646905
dc.authorwosidAkis, Tolga/P-6181-2014
dc.authorwosidEraslan, Ahmet Nedim/AAZ-9946-2020
dc.contributor.authorEraslan, AN
dc.contributor.authorAkis, T
dc.contributor.otherCivil Engineering
dc.date.accessioned2024-07-05T15:09:26Z
dc.date.available2024-07-05T15:09:26Z
dc.date.issued2005
dc.departmentAtılım Universityen_US
dc.department-tempMiddle E Tech Univ, Dept Engn Sci, TR-06531 Ankara, Turkey; Atilim Univ, Dept Civil Engn, TR-06836 Ankara, Incek, Turkeyen_US
dc.descriptionAkis, Tolga/0000-0002-6754-4497en_US
dc.description.abstractYielding of two-layer shrink-fitted composite tubes with axially constrained ends subject to either internal or external pressure is investigated in detail. In the framework of small deformations, a state of plane strain and von Mises yield criterion, analytical expressions are obtained for critical values of the pressure leading to plastic flow. It is shown that, depending on material properties and tube dimensions, different modes of plastic deformation may occur. Yielding may commence at the inner tube or at the outer tube or simultaneously in both tubes. The conditions for different nature of plastic flow are determined. Using analytical expressions obtained for critical values of the parameters and properties of real engineering materials, various numerical examples are handled and the variation of elastic limit pressure with interference and interface radius is explained.en_US
dc.identifier.citationcount13
dc.identifier.doi10.1007/s10010-005-0001-5
dc.identifier.endpage196en_US
dc.identifier.issn0015-7899
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-28544452344
dc.identifier.startpage187en_US
dc.identifier.urihttps://doi.org/10.1007/s10010-005-0001-5
dc.identifier.urihttps://hdl.handle.net/20.500.14411/1179
dc.identifier.volume69en_US
dc.identifier.wosWOS:000234495600001
dc.identifier.wosqualityQ4
dc.institutionauthorAkış, Tolga
dc.language.isoenen_US
dc.publisherSpringer Heidelbergen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.scopus.citedbyCount14
dc.subject[No Keyword Available]en_US
dc.titleYielding of Two-Layer Shrink-Fitted Composite Tubes Subject To Radial Pressureen_US
dc.typeArticleen_US
dc.wos.citedbyCount13
dspace.entity.typePublication
relation.isAuthorOfPublicationc5c8784e-c129-499c-8a15-85aa6cf5ce96
relation.isAuthorOfPublication.latestForDiscoveryc5c8784e-c129-499c-8a15-85aa6cf5ce96
relation.isOrgUnitOfPublication01fb4c5b-b45f-40c0-9a74-f0b3b6265a0d
relation.isOrgUnitOfPublication.latestForDiscovery01fb4c5b-b45f-40c0-9a74-f0b3b6265a0d

Files

Collections