Civil Engineering Department of Atılım University, this opportunity can be attained by two Master of Science programs (with thesis or non-thesis). These programs are divided into the following subdivisions: 1) Construction Management, 2) Materials of Construction, 3) Geotechnical Engineering, 4) Hydromechanics and Water Resources Engineering, 5) Structural Engineering and Mechanics, and 6) Transportation Engineering. So, you can find among these alternatives, a subdiscipline that focuses on your interests and allows you to work toward your career goals. Civil Engineering Department of Atılım University which has a friendly faculty comprised of members with degrees from renowned international universities, laboratories for both educational and research purposes, and other facilities like computer infrastructure and classrooms well-suited for a good graduate education.

Journal Issue

Abstract

Results of a study focusing on the flexural response of precast prestressed concrete hollow-core slabs with cast-in-place concrete topping are presented. The experimental part of the study included load testing of five precast concrete hollow-core units. The numerically determined flexural response of test specimens was later compared with the experimentally obtained behavior. Results demonstrate that a major composite action is valid between the hollow-core unit and the topping slab under load levels corresponding to uncracked state of the cross section. Existence of a topping slab resulted in improvements in the cracking moment and initial stiffness of hollow-core units. The beneficial effect of topping slab on the ultimate moment capacity was observed to be limited, mainly because of the loss of composite action prior to reaching the ultimate moment capacity. Horizontal shear strength at the interface between hollow-core unit and topping slab was determined (1) through limited number of pushoff load tests and (2) through calculations considering the load level corresponding to initiation of significant relative slip using the basic mechanics of materials approach and the simplified code expression. The measured and computed interface shear strength values were observed to be significantly lower than the horizontal shear strength values specified by the ACI and AASHTO Specifications. (C) 2015 Elsevier Ltd. All rights reserved.

Description

Baran, Eray/0000-0002-0240-803X

Keywords

Composite construction, Hollow-core slab, Prestressed concrete, Precast concrete, Horizontal shear strength