Reliability and Optimal Replacement Policy for a <i>k</I>-out-of-<i>n< System Subject To Shocks
dc.authorid | DEVRIM, YILSER/0000-0001-8430-0702 | |
dc.authorid | Eryilmaz, Serkan/0000-0002-2108-1781 | |
dc.authorscopusid | 8203625300 | |
dc.authorscopusid | 11139445500 | |
dc.authorwosid | DEVRIM, YILSER/AAF-8790-2019 | |
dc.authorwosid | Eryilmaz, Serkan/AAF-9349-2019 | |
dc.contributor.author | Eryilmaz, Serkan | |
dc.contributor.author | Devrim, Yilser | |
dc.contributor.other | Industrial Engineering | |
dc.contributor.other | Energy Systems Engineering | |
dc.date.accessioned | 2024-07-05T15:40:02Z | |
dc.date.available | 2024-07-05T15:40:02Z | |
dc.date.issued | 2019 | |
dc.department | Atılım University | en_US |
dc.department-temp | [Eryilmaz, Serkan] Atilim Univ, Dept Ind Engn, Ankara, Turkey; [Devrim, Yilser] Atilim Univ, Dept Energy Syst Engn, Ankara, Turkey | en_US |
dc.description | DEVRIM, YILSER/0000-0001-8430-0702; Eryilmaz, Serkan/0000-0002-2108-1781 | en_US |
dc.description.abstract | Consider a k-out-of-n system which is subject to shocks that occur at random times. Each shock causes failure of random number of components, and hence the system's lifetime corresponds to one of the arrival times of shocks. The reliability and mean time to failure of the system are studied when the times between shocks follow a phase type distribution. The optimal replacement time problem which is concerned with the minimization of the total long-run average cost per unit time is also defined and studied. | en_US |
dc.identifier.citationcount | 47 | |
dc.identifier.doi | 10.1016/j.ress.2019.03.045 | |
dc.identifier.endpage | 397 | en_US |
dc.identifier.issn | 0951-8320 | |
dc.identifier.issn | 1879-0836 | |
dc.identifier.scopus | 2-s2.0-85063541359 | |
dc.identifier.startpage | 393 | en_US |
dc.identifier.uri | https://doi.org/10.1016/j.ress.2019.03.045 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14411/3290 | |
dc.identifier.volume | 188 | en_US |
dc.identifier.wos | WOS:000470341400035 | |
dc.identifier.wosquality | Q1 | |
dc.institutionauthor | Eryılmaz, Serkan | |
dc.institutionauthor | Devrim, Yılser | |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Sci Ltd | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.scopus.citedbyCount | 61 | |
dc.subject | k-out-of-n system | en_US |
dc.subject | Optimal replacement time | en_US |
dc.subject | Phase-type distribution | en_US |
dc.title | Reliability and Optimal Replacement Policy for a <i>k</I>-out-of-<i>n< System Subject To Shocks | en_US |
dc.type | Article | en_US |
dc.wos.citedbyCount | 55 | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 37862217-5541-47e3-9406-e21aa38e7fdf | |
relation.isAuthorOfPublication | d9a1d14f-b12f-40ca-a17d-175c6f9c882a | |
relation.isAuthorOfPublication.latestForDiscovery | 37862217-5541-47e3-9406-e21aa38e7fdf | |
relation.isOrgUnitOfPublication | 12c9377e-b7fe-4600-8326-f3613a05653d | |
relation.isOrgUnitOfPublication | 80f84cab-4b75-401b-b4b1-f2ec308f3067 | |
relation.isOrgUnitOfPublication.latestForDiscovery | 12c9377e-b7fe-4600-8326-f3613a05653d |