Structural behavior of shear connectors embedded in different types of concrete

dc.contributor.authorWardi, Adil Hadi
dc.contributor.authorTunc, Gokhan
dc.contributor.authorIbraheem, Khalil
dc.contributor.otherCivil Engineering
dc.date.accessioned2024-10-06T11:32:45Z
dc.date.available2024-10-06T11:32:45Z
dc.date.issued2020
dc.departmentAtılım Universityen_US
dc.department-tempYabancı Kurumlar,ATILIM ÜNİVERSİTESİ,Yabancı Kurumlaren_US
dc.description.abstractPush-out tests are used to determine shear connectors’ properties where two smallreinforced concrete walls are attached to the top and bottom flanges of an I-sectionthrough four shear studs located on both its flanges. In this study, the structural behavior of shear connectors was examined by testing a total of 36 push-out specimens.In these specimens, various test parameters were used. The types of shear connectors and their strengths, their connection types, and the strength of the concrete inwhich they were embedded were all investigated. Headed, L-shaped, and C-shapedstuds were selected in this experimental study to represent different types of shearconnectors. These shear connectors were assumed to be either ordinary or highstrength steel-embedded in three different types of concrete: ordinary, high strength,and reactive powder concretes. In these tests, the shear connectors were connectedthrough welding or epoxy bonding. The objective of this study was to investigate thestructural behaviors of these different types of shear connectors by focusing on theirshear force capacities and slip values. The test results indicate that the reactive powder concrete increased the mechanical properties of concrete as the concrete age increased. The specimens with C-shaped studs made of high-strength steel with weldedstuds embedded in normal weight, high strength and reactive powder concretes, generated the maximum shear resistance values.en_US
dc.identifier.citationcount0
dc.identifier.endpage175en_US
dc.identifier.issn2149-8024
dc.identifier.issue4en_US
dc.identifier.scopusqualityN/A
dc.identifier.startpage160en_US
dc.identifier.trdizinid457536
dc.identifier.urihttps://search.trdizin.gov.tr/en/yayin/detay/457536/structural-behavior-of-shear-connectors-embedded-in-different-types-of-concrete
dc.identifier.urihttps://hdl.handle.net/20.500.14411/10027
dc.identifier.volume6en_US
dc.identifier.wosqualityN/A
dc.institutionauthorTunç, Gökhan
dc.language.isoenen_US
dc.relation.ispartofChallenge Journal of Structural Mechanicsen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleStructural behavior of shear connectors embedded in different types of concreteen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isAuthorOfPublication604a39c3-cb82-41d9-821a-ab76dc03e490
relation.isAuthorOfPublication.latestForDiscovery604a39c3-cb82-41d9-821a-ab76dc03e490
relation.isOrgUnitOfPublication01fb4c5b-b45f-40c0-9a74-f0b3b6265a0d
relation.isOrgUnitOfPublication.latestForDiscovery01fb4c5b-b45f-40c0-9a74-f0b3b6265a0d

Files

Collections