A fully automatic photogrammetric system design using a 1.3 MP web camera to determine EEG electrode positions;

No Thumbnail Available

Date

2010

Journal Title

Journal ISSN

Volume Title

Publisher

Open Access Color

OpenAIRE Downloads

OpenAIRE Views

Research Projects

Organizational Units

Organizational Unit
Computer Engineering
(1998)
The Atılım University Department of Computer Engineering was founded in 1998. The department curriculum is prepared in a way that meets the demands for knowledge and skills after graduation, and is subject to periodical reviews and updates in line with international standards. Our Department offers education in many fields of expertise, such as software development, hardware systems, data structures, computer networks, artificial intelligence, machine learning, image processing, natural language processing, object based design, information security, and cloud computing. The education offered by our department is based on practical approaches, with modern laboratories, projects and internship programs. The undergraduate program at our department was accredited in 2014 by the Association of Evaluation and Accreditation of Engineering Programs (MÜDEK) and was granted the label EUR-ACE, valid through Europe. In addition to the undergraduate program, our department offers thesis or non-thesis graduate degree programs (MS).

Journal Issue

Abstract

In this study a fully automatic fotogrammetric system is designed to determine the EEG electrode positions in 3D. The proposed system uses a 1.3 MP web camera rotating over the subject's head. The camera is driven by a step motor. The camera takes photos in every 7.20 angles during the rotation. In order to realize full automation, electrodes are labeled by colored circular markers and an electrode identification algorithm is develeoped for full automation. The proposed method is tested by using a realistic head phantom carrying 25 electrodes. The positions of the test electrodes are also measured by a conventional 3-D digitizer. The measurements are repeated 3 times for repeatibility purposes. It is found that 3-d digitizer localizes the electrodes with an average error of 8.46 mm, 7.63 mm and 8.32 mm, while the proposed system localizes the electrodes with an average error of 1.76 mm, 1.42 mm and 1.53 mm. ©2010 IEEE.

Description

Keywords

[No Keyword Available]

Turkish CoHE Thesis Center URL

Fields of Science

Citation

0

WoS Q

Scopus Q

Source

2010 15th National Biomedical Engineering Meeting, BIYOMUT2010 -- 2010 15th National Biomedical Engineering Meeting, BIYOMUT2010 -- 21 April 2010 through 24 April 2010 -- Antalya -- 80917

Volume

Issue

Start Page

End Page

Collections