Analysis of different methods of suppressing generator noise reaching indoor noise

No Thumbnail Available

Date

2022

Journal Title

Journal ISSN

Volume Title

Publisher

Open Access Color

OpenAIRE Downloads

OpenAIRE Views

Research Projects

Organizational Units

Organizational Unit
Architecture
(2009)
The Atılım University School of Architecture was founded in 2009. As for the number of students, our School is a medium-sized one, as is the case with many others in Europe. As a profession the expectation for which is to deal with people, society and environment in many aspects, architecture requires a similarly sophisticated education. In the Undergraduate Program at the Department of Architecture, we are working to establish such sophistication within the balance of theory and practice. Following the Integrated Doctorate Program that opened in 2010 for undergraduate and graduate alumni, the Thesis and Project Programs at Graduate Levels were opened in 2018. The self-evaluation studies of the Department that are run in coordination with the intra-evaluation and strategy studies of Atılım University are performed in relation to the external evaluations by the Architectural Accrediting Board (MİAK). The Department of Architecture is a member of the “European Association for Architectural Education” (EAAE).

Journal Issue

Abstract

The noise which occurs during the operation of the auxiliary power units is a disturbing factor, although its level varies depending on the environment. This high level of noise in occupational areas can cause not only health but also accidents risks. While silencers are mostly preferred for active noise control, acoustic foam or textile products are preferred according to passive control methods. In this review, the noises produced by the generators were examined and the studies in the literature on suppressing these noises were evaluated by making comparative analyzes. New recommendations have been developed according to the results of the comparative analysis. In case the sampled natural gas generator is closed with 2 mm thick plywood and a steel framed box covered with an acoustic sponge, the sound pressure level is approximately 30 dB in low frequency diesel + electric generators using a silencer according to active control methods. In measurements; It was observed that it decreased from 93.2 to 88.4 dB. While materials such as an acoustic sponge, which are preferred in passive control methods, are open-celled and porous structures, it is advantageous to have sound absorption capacity, but it can be a disadvantage due to its synthetic content.

Description

Keywords

Turkish CoHE Thesis Center URL

Fields of Science

Citation

0

WoS Q

N/A

Scopus Q

N/A

Source

European Mechanical Science

Volume

6

Issue

3

Start Page

161

End Page

178

Collections