Behavior of cold-formed steel wall panels under monotonic horizontal loading

No Thumbnail Available

Date

2012

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier Sci Ltd

Open Access Color

OpenAIRE Downloads

OpenAIRE Views

Research Projects

Organizational Units

Organizational Unit
Department of Civil Engineering
Civil Engineering Department of Atılım University, this opportunity can be attained by two Master of Science programs (with thesis or non-thesis). These programs are divided into the following subdivisions: 1) Construction Management, 2) Materials of Construction, 3) Geotechnical Engineering, 4) Hydromechanics and Water Resources Engineering, 5) Structural Engineering and Mechanics, and 6) Transportation Engineering. So, you can find among these alternatives, a subdiscipline that focuses on your interests and allows you to work toward your career goals. Civil Engineering Department of Atılım University which has a friendly faculty comprised of members with degrees from renowned international universities, laboratories for both educational and research purposes, and other facilities like computer infrastructure and classrooms well-suited for a good graduate education.

Journal Issue

Abstract

This paper summarizes the findings of an experimental study on cold-formed steel (CFS) wall panels with oriented strand board (OSB) sheathing. Static lateral load tests were conducted on a total of thirteen full-scale wall panel specimens to investigate the performance of CFS walls utilizing primarily the construction details used in Turkey. Experimental results revealed that the geometry of hold-down attachment used at the base of CFS wall panels to transfer tensile forces has a major effect on the overall behavior of the panels. Extensive damage was observed to occur in the hold-down attachment and in part of the bottom track adjacent to the hold-down, which prevented the wall panels to exhibit the stiffness associated with the main load resisting mechanisms. Tilting of the screws connecting the OSB sheathing to the CFS boundary framing members, as well as the separation of sheathing from the framing members were other commonly observed deformation modes. Existence of diagonal struts inside CFS frame was determined to cause a slight increase in load capacity and initial stiffness of the panels. It is also shown that the measured load capacity of wall panels can be predicted with an acceptable accuracy using design equations available in the literature. (C) 2012 Elsevier Ltd. All rights reserved.

Description

Baran, Eray/0000-0002-0240-803X

Keywords

Cold-formed steel, Wall panel, Sheathing, OSB panel

Turkish CoHE Thesis Center URL

Fields of Science

Citation

45

WoS Q

Q2

Scopus Q

Q1

Source

Volume

79

Issue

Start Page

1

End Page

8