Determination of Measurement Noise, Conductivity Errors and Electrode Mislocalization Effects To Somatosensory Dipole Localization

dc.contributor.author Şengül, Gökhan
dc.contributor.author Baysal, Uğur
dc.contributor.other Computer Engineering
dc.date.accessioned 2024-07-08T12:53:15Z
dc.date.available 2024-07-08T12:53:15Z
dc.date.issued 2012
dc.date.issuedtemp 2012-04-03
dc.description.abstract Calculating the spatial locations, directions and magnitudes of electrically active sources of human brain by using the measured scalp potentials is known as source localization. An accu rate source localization method requires not only EEG data but also the 3-D positions and number of measurement electrodes, the numerical head model of the patient/subject and the conductivities of the layers used in the head model. In this study we computationally deter mined the effect of noise, conductivity errors and electrode mislocalizations for electrical sources located in somatosensory cortex. We first randomly selected 1000 electric sources in somatosensory cortex, and for these sources we simulated the surface potentials by using av erage conductivities given in the literature and 3-D positions of the electrodes. We then added random noise to measurements and by using noisy data; we tried to calculate the positions of the dipoles by using different electrode positions or different conductivity values. The esti mated electrical sources and original ones are compared and by this way the effect of meas urement noise, electrode mislocalizations and conductivity errors to somatosensory dipole lo calization is investigated. We conclude that for an accurate somatosensory source localization method, we need noiseless measurements, accurate conductivity values of scalp and skull lay ers and the accurate knowledge of 3-D positions of measurement sensors.
dc.identifier.uri https://hdl.handle.net/20.500.14411/6425
dc.institutionauthor Şengül, Gökhan
dc.language.iso en
dc.publisher Biomedical Research
dc.subject computer engineering
dc.subject.other electrical & electronics engineering
dc.title Determination of Measurement Noise, Conductivity Errors and Electrode Mislocalization Effects To Somatosensory Dipole Localization
dc.type Article
dspace.entity.type Publication
relation.isAuthorOfPublication f291b4ce-c625-4e8e-b2b7-b8cddbac6c7b
relation.isAuthorOfPublication.latestForDiscovery f291b4ce-c625-4e8e-b2b7-b8cddbac6c7b
relation.isOrgUnitOfPublication e0809e2c-77a7-4f04-9cb0-4bccec9395fa
relation.isOrgUnitOfPublication.latestForDiscovery e0809e2c-77a7-4f04-9cb0-4bccec9395fa

Files

Collections