Kılıç, Erden

Loading...
Profile Picture
Name Variants
K.,Erden
E., Kılıç
Kilic E.
E.,Kilic
E.,Kiliç
Erden, Kilic
E., Kilic
Erden, Kılıç
K., Erden
Kilic,E.
Kilic, Erden
Kılıç,E.
E., Kiliç
Kiliç, Erden
E.,Kılıç
Kılıç, Erden
Erden, Kiliç
Job Title
Profesor Doktor
Email Address
erden.kilic@atilim.edu.tr
Main Affiliation
Department of Therapy and Rehabilitation
Status
Website
Scopus Author ID
Turkish CoHE Profile ID
Google Scholar ID
WoS Researcher ID

Sustainable Development Goals

NO POVERTY1
NO POVERTY
0
Research Products
ZERO HUNGER2
ZERO HUNGER
0
Research Products
GOOD HEALTH AND WELL-BEING3
GOOD HEALTH AND WELL-BEING
1
Research Products
QUALITY EDUCATION4
QUALITY EDUCATION
0
Research Products
GENDER EQUALITY5
GENDER EQUALITY
1
Research Products
CLEAN WATER AND SANITATION6
CLEAN WATER AND SANITATION
0
Research Products
AFFORDABLE AND CLEAN ENERGY7
AFFORDABLE AND CLEAN ENERGY
0
Research Products
DECENT WORK AND ECONOMIC GROWTH8
DECENT WORK AND ECONOMIC GROWTH
0
Research Products
INDUSTRY, INNOVATION AND INFRASTRUCTURE9
INDUSTRY, INNOVATION AND INFRASTRUCTURE
0
Research Products
REDUCED INEQUALITIES10
REDUCED INEQUALITIES
0
Research Products
SUSTAINABLE CITIES AND COMMUNITIES11
SUSTAINABLE CITIES AND COMMUNITIES
0
Research Products
RESPONSIBLE CONSUMPTION AND PRODUCTION12
RESPONSIBLE CONSUMPTION AND PRODUCTION
0
Research Products
CLIMATE ACTION13
CLIMATE ACTION
0
Research Products
LIFE BELOW WATER14
LIFE BELOW WATER
0
Research Products
LIFE ON LAND15
LIFE ON LAND
0
Research Products
PEACE, JUSTICE AND STRONG INSTITUTIONS16
PEACE, JUSTICE AND STRONG INSTITUTIONS
0
Research Products
PARTNERSHIPS FOR THE GOALS17
PARTNERSHIPS FOR THE GOALS
0
Research Products
Documents

23

Citations

310

h-index

9

Documents

16

Citations

237

Scholarly Output

7

Articles

7

Views / Downloads

65/262

Supervised MSc Theses

0

Supervised PhD Theses

0

WoS Citation Count

1

Scopus Citation Count

16

Patents

0

Projects

0

WoS Citations per Publication

0.14

Scopus Citations per Publication

2.29

Open Access Source

4

Supervised Theses

0

JournalCount
Acta Orthopaedica Belgica1
Joint Bone Spine1
Journal of Health Sciences and Medicine (Online)1
Medicine1
The Journal of Knee Surgery1
Current Page: 1 / 2

Scopus Quartile Distribution

Competency Cloud

GCRIS Competency Cloud

Scholarly Output Search Results

Now showing 1 - 1 of 1
  • Article
    Which Design Tolerates Rotational Mismatch Better in Unicompartmental Knee Arthroplasty: Fixed or Mobile Bearing?
    (Acta Medica Belgica, 2022) Emre, Fahri; Kilic, Erden; Kaya, Ozgur; Uysal, Ozgur Selim; Cay, Nurdan; Bozkurt, Murat; Erşen, Ömer
    Unicompartmental knee arthroplasty is an effective method for the treatment of medial compartment osteoarthritis. However, appropriate surgical technique and optimum implant positioning are crucial for a satisfactory outcome. This study aimed to demonstrate the relation between the clinical scores and the alignment of the components in UKA. A total of 182 patients with medial compartment osteoarthritis and treated by UKA between January 2012 and January 2017 were enrolled in this study. Computed tomography (CT) was used to measure the rotation of components. Patients were divided into two groups according to the insert design. These groups were divided into three subgroups according to the angle of the tibia relative to the femur (TFRA) (A): TFRA 0 degrees to 5 degrees either internal or external rotation; (B): TFRA >5 degrees internal rotation, and (C): TFRA >5 degrees external rotation. There was no significant difference between the groups in terms of age, body mass index (BMI) and follow-up period. KSS scores increased as the tibial component rotation (TCR) external rotation increased, but there was no correlation for WOMAC score. (P: 0,039 r: 0,207; P:0,347 r:0,095, respectively) Post-operative KSS and WOMAC scores decreased as TFRA external rotation was increased. (p: 0,001; p:0,001, respectively) No correlation has been observed between femoral component rotation (FCR) internal rotation and post-operative KSS and WOMAC scores. (p: 0,261; p: 0,502, respectively) Any mismatch between the components is better tolerated by mobile-bearing designs compared to fixed-bearing designs. Orthopedic surgeons should take care of rotational mismatch of components, not only the axial alignment of the components.