Browsing by Author "Zor, Zeynep Fatma"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Article Citation Count: 5Does the angulation of the mandibular third molar influence the fragility of the mandibular angle after trauma to the mandibular body? A three-dimensional finite-element study(Taylor & Francis Ltd, 2018) Kilinc, Yeliz; Zor, Zeynep Fatma; Tumer, Mehmet Kemal; Erkmen, Erkan; Kurt, AhmetThe relationship between mandibular third molar (M3) angulation and mandibular angle fragility is not well established. The aim of this study was to evaluate the impact of M3 angulation on the mandibular angle fragility when submitted to a trauma to the mandibular body region. A three-dimensional (3D) mandibular model without M3 (Model 0) was obtained by means of finite-element analysis (FEA). Four models were generated from the initial model, representing distoangular (Model D), horizontal (Model H), mesioangular (Model M) and vertical (Model V) angulations. A blunt trauma with a magnitude of 2000 N was applied perpendicularly to the sagittal plane in the mandibular body. Maximum principal stress (P-max) (tensile stress) values were calculated in the bone. The lowest P-max stress values were noted in Model 0. When the M3 was present extra stress fields were found around marginal bone of second molar and M3. Comparative analysis of the models with M3 revealed that the highest level of stress was found in Model V, whereas Model D showed the lowest stress values. The angulation of M3 affects the stress levels in the mandibular angle and has an impact on mandibular fragility. The mandibular angle becomes more fragile in case of vertical impaction when submitted to a trauma to the mandibular body region.Conference Object Citation Count: 2How do implant threads and diameters affect the all-on-four success? A 3D finite element analysis study(Ios Press, 2022) Zor, Zeynep Fatma; Kilinc, Yeliz; Erkmen, Erkan; Kurt, AhmetBACKGROUND: The effect of different thread designs and diameters on the all-on-four concept is unclear. OBJECTIVE: The aim of the study was to clarify the differences in stress distribution of dental implants with various thread designs and diameters based on the all-on-four concept with three dimensional (3D) finite element analysis (FEA). METHODS: A 3D model of a totally edentulous mandible was used to perform the FEA. Four different models (M1, M2, M3, and M4) including 3.5 and 4.3 mm diameter dental implants with active and passive threaded designs were generated. The dental implants were positioned according to the all-on-four concept. The Von Mises stresses on dental implants and maximum and minimum principal stresses (Pmax and Pmin) on bony structures were calculated under vertical, oblique and horizontal loads. RESULTS: For Von Mises stresses, the highest stress values were detected on the distal implants for all models. Distal implants had also the highest stress values for vertical loading. The Von Mises stresses were found to be concentrated around the implant's neck. In all models the highest Pmax and Pmin stresses occurred in the bone surrounding the distal implant. It was noted that the active threaded implants showed the highest Pmax and Pmin stress values. CONCLUSION: The implant thread design and diameter might have a strong influence on the stress values in the all-on-four concept.