1. Home
  2. Browse by Author

Browsing by Author "Amrani, Yassine"

Filter results by typing the first few letters
Now showing 1 - 2 of 2
  • Results Per Page
  • Sort Options
  • Loading...
    Thumbnail Image
    Article
    Citation - WoS: 3
    Citation - Scopus: 3
    Aptamer decorated PDA@magnetic silica microparticles for bacteria purification
    (Springer Wien, 2024) Kavruk, Murat; Babaie, Zahra; Kibar, Gunes; Cetin, Barbaros; Yesilkaya, Hasan; Amrani, Yassine; Ozalp, V. Cengiz; Basic Sciences; Nutrition and Dietetics
    One significant constraint in the advancement of biosensors is the signal-to-noise ratio, which is adversely affected by the presence of interfering factors such as blood in the sample matrix. In the present investigation, a specific aptamer binding was chosen for its affinity, while exhibiting no binding affinity towards non-target bacterial cells. This selective binding property was leveraged to facilitate the production of magnetic microparticles decorated with aptamers. A novel assay was developed to effectively isolate S. pneumoniae from PBS or directly from blood samples using an aptamer with an affinity constant of 72.8 nM. The capture experiments demonstrated efficiencies up to 87% and 66% are achievable for isolating spiked S. pneumoniae in 1 mL PBS and blood samples, respectively.
  • Loading...
    Thumbnail Image
    Article
    Citation - Scopus: 2
    Microfluidic Rapid Isolation and Electrochemical Detection of S. Pneumonia Via Aptamer-Decorated Surfaces
    (Elsevier, 2025) Babaie, Zahra; Kibar, Gunes; Yesilkaya, Hasan; Amrani, Yassine; Dogan, Soner; Tuna, Bilge G.; Cetin, Barbaros; Özalp, Veli Cengiz
    Background: S. pneumoniae is widely recognized as a leading cause of respiratory infections worldwide, often resulting in high mortality rates. However, the advent of microfluidic technologies has brought significant advancements, including the simplified, sensitive, cost-effective, and rapid approach to pneumococcal bacteremia detection. In this study, a microfluidic magnetic platform is presented for rapid isolation, and an electrode array is utilized for the electrochemical detection of S. pneumoniae. Aptamer-decorated surfaces were employed for both isolation and detection. For isolation, silica magnetic microparticles were synthesized and decorated with aptamer. Results: Isolation performance was assessed for phosphate-buffered saline (PBS) and blood samples for different concentrations of S. pneumoniae. Electrical impedance spectroscopy (EIS) with fabricated gold interdigitated electrodes (IDEs) decorated with aptamer was implemented for the detection of S. pneumoniae at different bacteria concentrations. The microfluidic platform performed bacteria isolation at comparable isolation efficiency with batch systems but at a much faster rate (isolation took about a minute, and the aptamer-decorated electrode array exhibited a limit of detection (LOD) at 962 CFU/mL and linear range between 104 and 107CFU/mL. Significance: Our method represents a significant advancement compared to previous reports. Our microfluidic platform can efficiently isolate 60 mu L of the bacteria sample within about one minute. The entire process takes about two minutes including the detection step. Furthermore, our method achieves a notable improvement in the detection limit for S. pneumoniae compared to conventional ELISA and magnetic microfluidics ELISA.