A Case Study on the Assumption of Mean Radiant Temperature Equals To Indoor Air Temperature in a Free-Running Building

dc.contributor.author Özbey, Mehmet Furkan
dc.contributor.author Turhan, Cihan
dc.contributor.other Energy Systems Engineering
dc.contributor.other Mechanical Engineering
dc.date.accessioned 2024-09-10T21:38:58Z
dc.date.available 2024-09-10T21:38:58Z
dc.date.issued 2021
dc.department Atılım University en_US
dc.department-temp ATILIM ÜNİVERSİTESİ,ATILIM ÜNİVERSİTESİ en_US
dc.description.abstract Thermal comfort is basically affected by environmental (mean radiant temperature, indoor air temperature and relative humidity and air velocity) and personal parameters (clothing value and activity level). Mean Radiant Temperature is the most complicated parameter among all thermal comfort parameters due to the difficulty of measurement and calculation processes. Calculation methods are not preferred by the researchers because of the complexity of obtaining angle factors while the measurement methods require very expensive devices such as globe thermometers and radiometers. On the other hand, assumptions are commonly used in thermal comfort studies because of their simplicities. One of the most frequently used assumptions expresses the equality of mean radiant temperature to indoor air temperature. However, the accuracy of this assumption needs further experimental research in order to evaluate thermal comfort, especially in free-running buildings. To this aim, this study proposes to determine the accuracy of the assumption of mean radiant temperature equals to indoor air temperature in a free-running building where Adaptive Thermal Comfort approach is applied in summer condition. Environmental parameters are measured via objective sensors, while adaptive thermal comfort is assessed by a software program. The statistical results show that there are significant deviations between two parameters in summer conditions for a free-running building. en_US
dc.identifier.citationcount 0
dc.identifier.doi 10.34088/kojose.833707
dc.identifier.endpage 85 en_US
dc.identifier.issn 2667-484X
dc.identifier.issue 1 en_US
dc.identifier.startpage 79 en_US
dc.identifier.trdizinid 1146081
dc.identifier.uri https://doi.org/10.34088/kojose.833707
dc.identifier.uri https://search.trdizin.gov.tr/tr/yayin/detay/1146081/a-case-study-on-the-assumption-of-mean-radiant-temperature-equals-to-indoor-air-temperature-in-a-free-running-building
dc.identifier.uri https://hdl.handle.net/20.500.14411/7528
dc.identifier.volume 4 en_US
dc.institutionauthor Özbey, Mehmet Furkan
dc.institutionauthor Turhan, Cihan
dc.language.iso en en_US
dc.relation.ispartof Kocaeli Journal of Science and Engineering en_US
dc.relation.publicationcategory Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı en_US
dc.rights info:eu-repo/semantics/openAccess en_US
dc.title A Case Study on the Assumption of Mean Radiant Temperature Equals To Indoor Air Temperature in a Free-Running Building en_US
dc.type Article en_US
dspace.entity.type Publication
relation.isAuthorOfPublication 702ce1f6-d478-4266-9092-b97ae8ec9f83
relation.isAuthorOfPublication 14edd55f-2035-410b-a400-63a1319bdfe5
relation.isAuthorOfPublication.latestForDiscovery 702ce1f6-d478-4266-9092-b97ae8ec9f83
relation.isOrgUnitOfPublication 80f84cab-4b75-401b-b4b1-f2ec308f3067
relation.isOrgUnitOfPublication d2cd5950-09a4-4d1d-976e-01f8f7ee4808
relation.isOrgUnitOfPublication.latestForDiscovery 80f84cab-4b75-401b-b4b1-f2ec308f3067

Files

Collections