A Case Study on the Assumption of Mean Radiant Temperature Equals to Indoor Air Temperature in a Free-Running Building

dc.contributor.authorÖzbey, Mehmet Furkan
dc.contributor.authorTurhan, Cihan
dc.contributor.otherEnergy Systems Engineering
dc.contributor.otherMechanical Engineering
dc.date.accessioned2024-09-10T21:38:58Z
dc.date.available2024-09-10T21:38:58Z
dc.date.issued2021
dc.departmentAtılım Universityen_US
dc.department-tempATILIM ÜNİVERSİTESİ,ATILIM ÜNİVERSİTESİen_US
dc.description.abstractThermal comfort is basically affected by environmental (mean radiant temperature, indoor air temperature and relative humidity and air velocity) and personal parameters (clothing value and activity level). Mean Radiant Temperature is the most complicated parameter among all thermal comfort parameters due to the difficulty of measurement and calculation processes. Calculation methods are not preferred by the researchers because of the complexity of obtaining angle factors while the measurement methods require very expensive devices such as globe thermometers and radiometers. On the other hand, assumptions are commonly used in thermal comfort studies because of their simplicities. One of the most frequently used assumptions expresses the equality of mean radiant temperature to indoor air temperature. However, the accuracy of this assumption needs further experimental research in order to evaluate thermal comfort, especially in free-running buildings. To this aim, this study proposes to determine the accuracy of the assumption of mean radiant temperature equals to indoor air temperature in a free-running building where Adaptive Thermal Comfort approach is applied in summer condition. Environmental parameters are measured via objective sensors, while adaptive thermal comfort is assessed by a software program. The statistical results show that there are significant deviations between two parameters in summer conditions for a free-running building.en_US
dc.identifier.citation0
dc.identifier.doi10.34088/kojose.833707
dc.identifier.endpage85en_US
dc.identifier.issn2667-484X
dc.identifier.issue1en_US
dc.identifier.scopusqualityN/A
dc.identifier.startpage79en_US
dc.identifier.trdizinid1146081
dc.identifier.urihttps://doi.org/10.34088/kojose.833707
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/1146081/a-case-study-on-the-assumption-of-mean-radiant-temperature-equals-to-indoor-air-temperature-in-a-free-running-building
dc.identifier.urihttps://hdl.handle.net/20.500.14411/7528
dc.identifier.volume4en_US
dc.identifier.wosqualityN/A
dc.language.isoenen_US
dc.relation.ispartofKocaeli Journal of Science and Engineeringen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleA Case Study on the Assumption of Mean Radiant Temperature Equals to Indoor Air Temperature in a Free-Running Buildingen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isAuthorOfPublication702ce1f6-d478-4266-9092-b97ae8ec9f83
relation.isAuthorOfPublication14edd55f-2035-410b-a400-63a1319bdfe5
relation.isAuthorOfPublication.latestForDiscovery702ce1f6-d478-4266-9092-b97ae8ec9f83
relation.isOrgUnitOfPublication80f84cab-4b75-401b-b4b1-f2ec308f3067
relation.isOrgUnitOfPublicationd2cd5950-09a4-4d1d-976e-01f8f7ee4808
relation.isOrgUnitOfPublication.latestForDiscovery80f84cab-4b75-401b-b4b1-f2ec308f3067

Files

Collections