This work presents the pioneering development of an aptamer-based electrochemical biosensor for real-time monitoring of parathyroid hormone (PTH) levels, with a focus on intraoperative assessment during parathyroid surgery. It introduces, for the first time, the selection and characterization of aptamers targeting distinct segments of the PTH peptide. The study demonstrates the feasibility and efficacy of the biosensing platform through a precisely designed experimental framework, including SELEX-based aptamer selection, aptamer-peptide interaction analysis, and biosensor fabrication. The SELEX process yields aptamers with notable binding affinities to different fragments of PTH, with the PTH (53-84) aptamer showing particularly sensitive binding to the hormone's C terminus, allowing for precise PTH analysis. Electrochemical characterization reveals significant changes in electrochemical impedance spectroscopy (EIS) signals upon exposure to varying PTH concentrations, highlighting the sensor's sensitivity and selectivity. The increase in charge transfer resistance (Rct) values with rising PTH concentrations underscores the biosensor's capability to detect PTH-induced structural changes, validating its potential for accurate measurement. The biosensor shows remarkable selectivity in the presence of common interferents in serum samples, ensuring precise PTH detection. Stability assessments over a 45-day storage period demonstrate the biosensor's robustness and long-term reliability, affirming its practical suitability. In summary, the developed aptamer-based biosensor represents a promising tool for sensitive and selective PTH detection, with potential applications in biomedical research and clinical diagnostics, particularly for intraoperative PTH analysis during parathyroidectomy. Continued research and optimization efforts hold promise for enhancing its performance and expanding its utility in diverse healthcare settings.

Description

Keywords

Aptamer, Electrochemical Detection, Electrochemical Impedance Spectroscopy (EIS), Impedimetric Biosensor, Parathyroid Hormone (PTH), Selex, Original Article, Parathyroid Hormone, Dielectric Spectroscopy, SELEX Aptamer Technique, Humans, Biosensing Techniques, Electrochemical Techniques, Aptamers, Nucleotide

Fields of Science

Citation

WoS Q

Q3

Scopus Q

Q2
OpenCitations Logo
OpenCitations Citation Count
N/A

Source

Biotechnology and Applied Biochemistry

Volume

72

Issue

Start Page

1351

End Page

1362

Collections

PlumX Metrics
Citations

Scopus : 0

Captures

Mendeley Readers : 3

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.0

Sustainable Development Goals

SDG data is not available