Biomechanical Comparison of Two Different Collar Structured Implants Supporting 3-Unit Fixed Partial Denture: a 3-D Fem Study
Loading...

Date
2012
Journal Title
Journal ISSN
Volume Title
Publisher
Taylor & Francis Ltd
Open Access Color
Green Open Access
No
OpenAIRE Downloads
OpenAIRE Views
Publicly Funded
No
Abstract
Objective. The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone as well as in the fixture-abutment complex, in the framework and in the veneering material of 3-unit fixed partial denture (FPD). Material and methods. The 3-dimensional finite element analysis method was selected to evaluate the stress distribution in the system composed of 3-unit FPD supported by two different dental implant systems with two distinct collar geometries; microthread collar structure (MCS) and non-microthread collar structure (NMCS). In separate load cases, 300 N vertical, 150 N oblique and 60 N horizontal, forces were utilized to simulate the multidirectional chewing forces. Tensile and compressive stress values in the cortical and cancellous bone and von Mises stresses in the fixture-abutment complex, in the framework and veneering material, were simulated as a body and investigated separately. Results. In the cortical bone lower stress values were found in the MCS model, when compared with NMCS. In the cancellous bone, lower stress values were observed in the NMCS model when compared with MCS. In the implant-abutment complex, highest von Mises stress values were noted in the NMCS model; however, in the framework and veneering material, highest stress values were calculated in MCS model. Conclusions. MCS implants when compared with NMCS implants supporting 3-unit FPDs decrease the stress values in the cortical bone and implant-abutment complex. The results of the present study will be evaluated as a base for our ongoing FEA studies focused on stress distribution around the microthread and non-microthread collar geometries with various prosthesis design.
Description
Özden, Utku Ahmet/0000-0003-0463-7036; ERKMEN, Erkan/0000-0002-4746-5281
Keywords
dental stress analysis, implant, prosthodontics, Dental Implants, Dental Stress Analysis, Imaging, Three-Dimensional, Compressive Strength, Dental Prosthesis Design, Tensile Strength, Finite Element Analysis, Denture, Partial, Fixed, Dental Implant-Abutment Design, Dental Prosthesis, Implant-Supported, Biomechanical Phenomena
Fields of Science
03 medical and health sciences, 0302 clinical medicine
Citation
WoS Q
Q2
Scopus Q
Q2

OpenCitations Citation Count
18
Source
Acta Odontologica Scandinavica
Volume
70
Issue
1
Start Page
61
End Page
71
PlumX Metrics
Citations
CrossRef : 10
Scopus : 20
PubMed : 5
Captures
Mendeley Readers : 44
SCOPUS™ Citations
20
checked on Mar 21, 2026
Web of Science™ Citations
14
checked on Mar 21, 2026
Google Scholar™


