Biomechanical Comparison of Two Different Collar Structured Implants Supporting 3-Unit Fixed Partial Denture: a 3-D Fem Study

Loading...
Publication Logo

Date

2012

Journal Title

Journal ISSN

Volume Title

Publisher

Taylor & Francis Ltd

Open Access Color

Green Open Access

No

OpenAIRE Downloads

OpenAIRE Views

Publicly Funded

No
Impulse
Average
Influence
Top 10%
Popularity
Top 10%

Research Projects

Journal Issue

Abstract

Objective. The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone as well as in the fixture-abutment complex, in the framework and in the veneering material of 3-unit fixed partial denture (FPD). Material and methods. The 3-dimensional finite element analysis method was selected to evaluate the stress distribution in the system composed of 3-unit FPD supported by two different dental implant systems with two distinct collar geometries; microthread collar structure (MCS) and non-microthread collar structure (NMCS). In separate load cases, 300 N vertical, 150 N oblique and 60 N horizontal, forces were utilized to simulate the multidirectional chewing forces. Tensile and compressive stress values in the cortical and cancellous bone and von Mises stresses in the fixture-abutment complex, in the framework and veneering material, were simulated as a body and investigated separately. Results. In the cortical bone lower stress values were found in the MCS model, when compared with NMCS. In the cancellous bone, lower stress values were observed in the NMCS model when compared with MCS. In the implant-abutment complex, highest von Mises stress values were noted in the NMCS model; however, in the framework and veneering material, highest stress values were calculated in MCS model. Conclusions. MCS implants when compared with NMCS implants supporting 3-unit FPDs decrease the stress values in the cortical bone and implant-abutment complex. The results of the present study will be evaluated as a base for our ongoing FEA studies focused on stress distribution around the microthread and non-microthread collar geometries with various prosthesis design.

Description

Özden, Utku Ahmet/0000-0003-0463-7036; ERKMEN, Erkan/0000-0002-4746-5281

Keywords

dental stress analysis, implant, prosthodontics, Dental Implants, Dental Stress Analysis, Imaging, Three-Dimensional, Compressive Strength, Dental Prosthesis Design, Tensile Strength, Finite Element Analysis, Denture, Partial, Fixed, Dental Implant-Abutment Design, Dental Prosthesis, Implant-Supported, Biomechanical Phenomena

Fields of Science

03 medical and health sciences, 0302 clinical medicine

Citation

WoS Q

Q2

Scopus Q

Q2
OpenCitations Logo
OpenCitations Citation Count
18

Source

Acta Odontologica Scandinavica

Volume

70

Issue

1

Start Page

61

End Page

71

Collections

PlumX Metrics
Citations

CrossRef : 10

Scopus : 20

PubMed : 5

Captures

Mendeley Readers : 44

SCOPUS™ Citations

20

checked on Mar 21, 2026

Web of Science™ Citations

14

checked on Mar 21, 2026

Google Scholar Logo
Google Scholar™
OpenAlex Logo
OpenAlex FWCI
0.9107

Sustainable Development Goals

SDG data is not available