Hardware-In-The-Loop Assessment of a Fault Tolerant Fuzzy Control Scheme for an Offshore Wind Farm Simulator

No Thumbnail Available

Date

2022

Journal Title

Journal ISSN

Volume Title

Publisher

Elsevier

Open Access Color

OpenAIRE Downloads

OpenAIRE Views

Research Projects

Organizational Units

Organizational Unit
Energy Systems Engineering
(2009)
The Department of Energy Systems Engineering admitted its first students and started education in the academic year of 2009-2010 under Atılım University School of Engineering. In this Department, all kinds of energy are presented in modules (conventional energy, renewable energy, hydrogen energy, bio-energy, nuclear energy, energy planning and management) from their detection, production and procession; to their transfer and distribution. A need is to arise for a surge of energy systems engineers to ensure energy supply security and solve environmental issues as the most important problems of the fifty years to come. In addition, Energy Systems Engineering is becoming among the most important professions required in our country and worldwide, especially within the framework of the European Union harmonization process, and within the free market economy.

Journal Issue

Abstract

To enhance both the safety and the efficiency of offshore wind park systems, faults must be accommodated in their earlier occurrence, in order to avoid costly unplanned maintenance. Therefore, this paper aims at implementing a fault tolerant control strategy by means of a data-driven approach relying on fuzzy logic. In particular, fuzzy modelling is considered here as it enables to approximate unknown nonlinear relations, while managing uncertain measurements and disturbance. On the other hand, the model of the fuzzy controller is directly estimated from the input-output signals acquired from the wind farm system, with fault tolerant capabilities. In general, the use of purely nonlinear relations and analytic methods would require more complex design tools. The design is therefore enhanced by the use of fuzzy model prototypes obtained via a data-driven approach, thus representing the key point if real-time solutions have to implement the proposed fault tolerant control strategy. Finally, a high-fidelity simulator relying on a hardware-in-the-loop tool is exploited to verify and validate the reliability and robustness characteristics of the developed methodology also for on-line and more realistic implementations. Copyright (C) 2022 The Authors.

Description

Simani, Silvio/0000-0003-1815-2478

Keywords

Fault tolerant control, fuzzy logic, data-driven approach, hardware-in-the-loop tool, offshore wind park

Turkish CoHE Thesis Center URL

Fields of Science

Citation

0

WoS Q

Scopus Q

Q3

Source

11th International-Federation-of-Automatic-Control (IFAC) Symposium on Fault Detection, Supervision and Safety for Technical Processes (SAFEPROCESS) -- JUN 08-10, 2022 -- Pafos, CYPRUS

Volume

55

Issue

6

Start Page

390

End Page

395