A New Extended <i>δ</I>-shock Model With the Consideration of Shock Magnitude
dc.authorscopusid | 57210794714 | |
dc.authorscopusid | 8203625300 | |
dc.contributor.author | Lorvand, Hamed | |
dc.contributor.author | Eryılmaz, Serkan | |
dc.contributor.author | Eryilmaz, Serkan | |
dc.contributor.other | Industrial Engineering | |
dc.date.accessioned | 2024-09-10T21:33:27Z | |
dc.date.available | 2024-09-10T21:33:27Z | |
dc.date.issued | 2024 | |
dc.department | Atılım University | en_US |
dc.department-temp | [Lorvand, Hamed] Isfahan Univ Technol, Dept Math Sci, Esfahan, Iran; [Eryilmaz, Serkan] Atilim Univ, Dept Ind Engn, Ankara, Turkiye | en_US |
dc.description.abstract | In this article, a new delta$$ \delta $$-shock model that takes into account the magnitude of shocks is introduced and studied from reliability perspective. According to the new model, the system breaks down if either a shock after non-critical shock occurs in a time length less than delta 1$$ {\delta}_1 $$ or a shock after a critical shock occurs in a time length less than delta 2,$$ {\delta}_2, $$ where delta 1<delta 2$$ {\delta}_1<{\delta}_2 $$. The distribution of the system's lifetime is studied for both discrete and continuous intershock time distributions. It is shown that a new model is useful to describe a certain cold standby repairable system. | en_US |
dc.description.sponsorship | The authors thank the anonymous referees for their helpful comments and suggestions, which were useful in improving the article. | en_US |
dc.description.woscitationindex | Science Citation Index Expanded | |
dc.identifier.citation | 0 | |
dc.identifier.doi | 10.1002/asmb.2884 | |
dc.identifier.issn | 1524-1904 | |
dc.identifier.issn | 1526-4025 | |
dc.identifier.scopus | 2-s2.0-85198524358 | |
dc.identifier.scopusquality | Q3 | |
dc.identifier.uri | https://doi.org/10.1002/asmb.2884 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14411/7286 | |
dc.identifier.wos | WOS:001272399100001 | |
dc.identifier.wosquality | Q3 | |
dc.language.iso | en | en_US |
dc.publisher | Wiley | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | matrix-geometric distribution | en_US |
dc.subject | probability generating function | en_US |
dc.subject | reliability | en_US |
dc.subject | shock model | en_US |
dc.title | A New Extended <i>δ</I>-shock Model With the Consideration of Shock Magnitude | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | 37862217-5541-47e3-9406-e21aa38e7fdf | |
relation.isAuthorOfPublication.latestForDiscovery | 37862217-5541-47e3-9406-e21aa38e7fdf | |
relation.isOrgUnitOfPublication | 12c9377e-b7fe-4600-8326-f3613a05653d | |
relation.isOrgUnitOfPublication.latestForDiscovery | 12c9377e-b7fe-4600-8326-f3613a05653d |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- A new extended -shock model with the consideration of Lorvand-Eryilmaz-ASMB.pdf
- Size:
- 149.73 KB
- Format:
- Adobe Portable Document Format